Search MEDLINE/PubMed
Title: Sonographic heat generation in vivo in the gravid long-tailed macaque (Macaca fascicularis). Author: Tarantal AF, Chu F, O'Brien WD, Hendrickx AG. Journal: J Ultrasound Med; 1993 May; 12(5):285-95. PubMed ID: 8345557. Abstract: Temperature elevations that occur during diagnostic ultrasonic exposure were assessed in vivo in gravid macaques after 10, 20, or 30 min (scan mode; N = 30) or 5, 10, or 15 min (pulsed Doppler; N = 32). Five time points were assessed during the second and third trimesters (gestational days 70 to 150 +/- 2; term, approximately 165 days) using a transient thermocouple technique. Measurements were obtained intracranially or at the muscle-bone interface using a commercial sector scanner (ATL MK 600, 7.5 MHz scanhead; scan mode, ISPTA) = 27 mW/cm2, ISPPA = 85 W/cm2, pulse repetition frequency (PRF) = 1 kHz; pulsed Doppler - ISPTA = 54 mW/cm2, ISPPA = 1.5 W/cm2, PRF = 18.5 kHz). Overall, the greatest temperature elevation achieved with either modality or location was 0.6 degrees C.[Abstract] [Full Text] [Related] [New Search]