Title: Clinical correlates of sudden auditory-vestibular loss in a cochlear implant patient. Author: Luetje CM, Mediavilla SJ, Geier LL. Journal: Ear Nose Throat J; 1993 Jul; 72(7):452-9. PubMed ID: 8354156. Abstract: The precise electrophysiologic mechanism for sudden sensorineural auditory-vestibular loss has yet to be defined. No human models exist for this idiopathic phenomenon. A 67-year-old cochlear implant (CI) patient experienced what could be termed a "typical" acute sudden auditory-vestibular loss. Vestibular and CI electrical psychophysical changes were monitored over a 22-month period. Once the acute vestibular problems diminished, CI electrical parameters returned to near pre-episode levels. Some improvement occurred in rotational chair phase lag and asymmetry. While improving, platform posturography continued to show difficulty performing sensory organization tests V and VI. These clinical findings may imply that ganglion cell and neuronal population are responsible for the auditory findings in sudden auditory-vestibular loss. Secondly, a CI patient may serve as an ideal human model for further study of this phenomenon, should it occur.[Abstract] [Full Text] [Related] [New Search]