These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Clinical correlates of sudden auditory-vestibular loss in a cochlear implant patient.
    Author: Luetje CM, Mediavilla SJ, Geier LL.
    Journal: Ear Nose Throat J; 1993 Jul; 72(7):452-9. PubMed ID: 8354156.
    Abstract:
    The precise electrophysiologic mechanism for sudden sensorineural auditory-vestibular loss has yet to be defined. No human models exist for this idiopathic phenomenon. A 67-year-old cochlear implant (CI) patient experienced what could be termed a "typical" acute sudden auditory-vestibular loss. Vestibular and CI electrical psychophysical changes were monitored over a 22-month period. Once the acute vestibular problems diminished, CI electrical parameters returned to near pre-episode levels. Some improvement occurred in rotational chair phase lag and asymmetry. While improving, platform posturography continued to show difficulty performing sensory organization tests V and VI. These clinical findings may imply that ganglion cell and neuronal population are responsible for the auditory findings in sudden auditory-vestibular loss. Secondly, a CI patient may serve as an ideal human model for further study of this phenomenon, should it occur.
    [Abstract] [Full Text] [Related] [New Search]