These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [A successful insertion of the prosthetic valve in supraannular position concomitant with pericardial enlargement of the aortic root in a child: a case report].
    Author: Watanabe H, Eguchi S, Miyamura H, Hayashi J, Sugawara M, Shinonaga M, Sato I, Sato S.
    Journal: Kyobu Geka; 1993 Aug; 46(9):771-4. PubMed ID: 8361102.
    Abstract:
    A 4-year-old boy admitted to our hospital due to congestive heart failure one year after the intracardiac repair of tetralogy of Fallot. Echocardiography and cineangiography revealed severe aortic regurgitation. The aortic valve replacement was performed with a prosthesis larger than the aortic annulus. Operative findings showed that the cause of aortic regurgitation was infective endocarditis. The aortic root was enlarged with pericardial patch and a 21 mm St. Jude Medical valve prosthesis was inserted in supraannular position. This technique was very useful for insertion of a prosthetic valve one or two sizes larger than the aortic annulus without risk of distorting the mitral valve or left ventricular function.
    [Abstract] [Full Text] [Related] [New Search]