These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Predictability of creatinine clearance estimates in critically ill patients. Author: Robert S, Zarowitz BJ, Peterson EL, Dumler F. Journal: Crit Care Med; 1993 Oct; 21(10):1487-95. PubMed ID: 8403957. Abstract: OBJECTIVES: a) To evaluate the predictive ability of different creatinine clearance methods as compared with the criterion standard, inulin clearance; and b) to determine which of the predictive methods yields the most accurate estimation of creatinine clearance. DESIGN: Prospective study. SETTING: Medical intensive care unit (ICU) of a university-affiliated tertiary care hospital. INTERVENTIONS: Glomerular filtration rate was measured by the criterion standard, inulin clearance. PATIENTS: Twenty mechanically ventilated adults. MEASUREMENTS: Renal function was assessed by the following procedures: inulin clearance using a standard protocol, 30-min creatinine clearance, 24-hr creatinine clearance, and creatinine clearance estimates by the Cockcroft-Gault equation. Ideal body weight, total body weight or lean body mass with actual serum creatinine or serum creatinine concentration corrected to 1 mg/dL (85 mumol/L) in cachectic patients were sequentially incorporated into the Cockcroft-Gault equation. RESULTS: The Cockcroft-Gault equation, using ideal body weight and the corrected serum creatinine concentration, was the best predictor of inulin clearance with the smallest bias (9.7 +/- 8.6, 95% confidence interval 5.7 to 13.8). The bias encountered with the 30-min creatinine clearance was not different from that value with the 24-hr creatinine clearance (21.6 +/- 33.0, 95% confidence interval 6.2 to 37.1 vs. 25.4 +/- 28.3, 95% confidence interval 11.8 to 42.9). Good correlations existed between inulin clearance and the Cockcroft-Gault equation, using ideal body weight and the corrected serum creatinine concentration (r2 = .81; p = .0001), as well as between inulin clearance and the Cockcroft-Gault equation, using the lower of ideal or total body weight and the higher of the actual serum creatinine concentration or corrected serum creatinine (r2 = .75; p = .0001). The 30-min creatinine clearance and the 24-hr creatinine clearance had poorer agreement with inulin clearance. The incorporation of a corrected serum creatinine value into the Cockcroft-Gault equation consistently led to better predictions and higher correlation coefficients. CONCLUSIONS: The utilization of the Cockcroft-Gault equation as used clinically (the lower of ideal or total body weight and the higher of actual serum creatinine or corrected serum creatinine concentration to 1 mg/dL [85 mumol/L]) results in more accurate predictions of glomerular filtration rate in the medical, critically ill patient than urine creatinine clearance measures. If creatinine clearance measures are used, the 30-min collection provided results not different from those results obtained with 24-hr urinary collections.[Abstract] [Full Text] [Related] [New Search]