These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Radiotherapy of the R1H-tumor: dose-rate effect on tumor response in brachytherapy with 106-ruthenium eye applicators.
    Author: Kleineidam M, Guthoff R, Schiller F, Chumbley L, Beck-Bornholdt HP.
    Journal: Int J Radiat Oncol Biol Phys; 1993 Jan 15; 25(2):277-81. PubMed ID: 8420875.
    Abstract:
    PURPOSE: The influence of the dose-rate on tumor response in radiotherapy with 106-Ruthenium eye plaques has been investigated in an experimental tumor system. MATERIALS AND METHODS: The identical total dose was applied within three different overall treatment times (42 hr, 192 hr and 312 hr), corresponding to dose-rates of 6.0 Gy/hr, 1.3 Gy/hr and 0.8 Gy/hr. RESULTS: The therapeutic outcome of brachytherapy varied significantly between the three groups of animals treated with different dose-rates. At a dose-rate of 1.3 Gy/hr all tumors were locally controlled, but no local control was observed when a dose-rate of 6.0 Gy/hr was delivered. 0.8 Gy/hr was less effective than 1.3 Gy/hr but more effective than 6.0 Gy/hr. CONCLUSION: These results were unexpected but they might be explained by an incomplete reoxygenation if the overall treatment time is too short (42 hr, dose-rate 6.0 Gy/hr) and by proliferation of tumor cells under treatment if the overall treatment time is too long (312 hr, 0.8 Gy/hr).
    [Abstract] [Full Text] [Related] [New Search]