These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Arterial blood pressure measurement technique. Author: Gorny DA. Journal: AACN Clin Issues Crit Care Nurs; 1993 Feb; 4(1):66-80. PubMed ID: 8452745. Abstract: Arterial blood pressure (BP) measurements, which include invasive direct methods and noninvasive indirect methods, provide a picture of the hemodynamic status of the patient. Invasive BP methods measure pressure pulse wave amplitude; noninvasive methods rely on blood flow or arterial wall motion as a basis for the determination of BP values. To obtain the most accurate BP value, the clinician must identify which measurement variables in a specific clinical situation are most contributory to error and, if possible, use a method of measurement for which the sources of error are not parallel. Blood pressure values obtained by different methods cannot be compared without a thorough understanding of the user-related and instrumentation-related limitations associated with each BP measurement technique.[Abstract] [Full Text] [Related] [New Search]