  • Title: One-step competitive immunochromatographic assay for semiquantitative determination of lipoprotein(a) in plasma.
    Author: Lou SC, Patel C, Ching S, Gordon J.
    Journal: Clin Chem; 1993 Apr; 39(4):619-24. PubMed ID: 8472355.
    Abstract:
    Numerous studies have associated high concentrations of lipoprotein(a) [Lp(a)] with atherosclerosis. We developed a rapid, one-step competitive immunochromatographic assay to measure Lp(a) in plasma. The assay is performed on a nitrocellulose membrane strip and the result is determined by a visual readout of rust-colored colloidal selenium. The assay is based on the principle that Lp(a) in the sample will compete with Lp(a)-coated colloidal selenium for binding to the anti-Lp(a) monoclonal antibody immobilized on the assay strip in the format of four ladder bars. The number of capture bars that appear as a result of the formation of colloidal selenium color is proportional to the concentration of the Lp(a) protein in the samples. The strip assay semiquantitatively measures Lp(a) concentrations ranging from 0 to 180 mg/L of Lp(a) protein in serum, plasma, or fingerstick whole-blood samples. This assay appears very useful for quick identification of individuals with above-normal concentrations of plasma Lp(a) protein (> 70 mg/L), and has potential for monitoring a patient's response to treatment with Lp(a)-lowering drugs.