These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Adaptation of pressure support ventilation to increasing ventilatory demand during experimental airway obstruction and acute lung injury. Author: Räsänen J, León MA, Cane RD. Journal: Crit Care Med; 1993 Apr; 21(4):562-6. PubMed ID: 8472577. Abstract: OBJECTIVE: To estimate the changes in the relative amount of ventilatory assistance offered by inspiratory pressure support during changing ventilatory demand with external airway obstruction and with oleic acid-induced acute lung injury. DESIGN: Prospective, controlled, crossover study. SETTING: Experimental laboratory in a university anesthesiology department. SUBJECTS: Eight dogs anesthetized with pentobarbital. INTERVENTIONS: An external resistor was placed in the breathing circuit to produce increased resistance to breathing. Acute lung injury was produced with oleic acid. Ventilatory demand was increased by increasing the CO2 concentration in inspired gas to produce an increase of 20 torr (2.7 kPa) in end-tidal CO2 tension. During airway obstruction, pressure support was adjusted to reduce the inspiratory decrease in intrathoracic pressure to the level present during unobstructed breathing. During acute lung injury, pressure support was applied to reduce the maximum negative deflection of intrathoracic pressure by 50%. MEASUREMENTS AND MAIN RESULTS: The ventilator effort was estimated by calculating the pressure-time integral of proximal airway pressure; the spontaneous ventilatory effort was estimated in a similar manner from esophageal pressure. The pressure support averaged 10 +/- 3 cm H2O during airway obstruction and 7 +/- 2 cm H2O during lung injury. The CO2 challenge effected an average increase in mean minute ventilation of 78% during airway obstruction (p < .001) and 120% during acute lung injury (p < .01). The augmentation of minute ventilation was accomplished by increasing the ventilatory rate and the transpulmonary pressure while inspiratory time remained unchanged. The pressure-time integrals measured using both airway (p < .001) and esophageal pressure (p < .01) increased significantly during each CO2 challenge, reflecting an increase in the contribution of both the ventilator and the animal to the required breathing effort. Significant decreases in the relative magnitude of the ventilator effort both during airway obstruction (p < .05) and during lung injury (p < .01) indicated that the increase in the spontaneous effort was predominant over the increase in mechanical ventilatory support. CONCLUSIONS: A ventilatory rate-dependent adaptation of pressure support to increased ventilatory demand occurs in an experimental setting both during airway obstruction and lung injury. The results of this study confirm an advantage of breath-to-breath inspiratory pressure support over techniques designed to supply a predetermined mechanical minute volume.[Abstract] [Full Text] [Related] [New Search]