These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Initial experiences with dilatation of dialysis shunts with color-coded duplex ultrasonography monitoring].
    Author: Wittenberg G, Kellner M, Kenn W, Obert A, Schultz G, Trusen A, Tschammler A, Götz R, Hahn D.
    Journal: Rofo; 1996 Jan; 164(1):38-41. PubMed ID: 8630358.
    Abstract:
    PURPOSE: Aim of the study was to evaluate the technical aspects of colour coded duplex sonography guided interventions of peripheral vessels. METHODS: During 15 months 39 stenoses of shunt veins in 24 patients were dilated guided by colour coded duplex sonography. RESULTS: 38 stenoses were dilated without complications. The blood flow volume was increased from 361.9 +/- 83.5 to 718.9 +/- 189.2 ml/min. In one case it was not possible to dilate the stenosis because of a vasospasm. CONCLUSION: PTA guided by colour coded duplex sonography is an alternative to DSA guided interventions of superficial vessels without x-ray exposure or contrast agent application.
    [Abstract] [Full Text] [Related] [New Search]