These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Ultrasound monitoring in cannulation of the internal jugular vein: anatomic and technical considerations.
    Author: Docktor B, So CB, Saliken JC, Gray RR.
    Journal: Can Assoc Radiol J; 1996 Jun; 47(3):195-201. PubMed ID: 8640417.
    Abstract:
    OBJECTIVE: To examine the effect of variations in anatomic features and operator experience on the success and complication rates of sonographically monitored cannulation of the internal jugular vein. PATIENTS AND METHODS: The authors prospectively collected data for ultrasound-monitored cannulation of the internal jugular vein in 150 patients. In all cases the radiologist recorded the side of puncture, the number of passes needed, the number of vein punctures (one or two), whether the walls were opposed during puncture and any complications. For the last 80 patients the following information was also recorded: the distance from the skin to the internal jugular vein, the diameter of the vein with the Valsalva manoeuvre and the location of the vein relative to the carotid artery. All but three of the cannulations were performed by one of three radiologists, all of whom had at least 5 years of experience. RESULTS: Cannulation was successful in all of the patients, and the first pass was successful in 133 (88.7%). These results are better than those of blind placement techniques reported in the literature. The only complications were hematoma and carotid puncture, which both occurred in the same two patients (1.3%). There was no significant difference among the radiologists in the number of passes needed (one-way analysis of variance, p > 0.05). The number of passes was independent of anatomic factors, including depth from skin, vein diameter or relative location. However, significantly more passes were needed for left-side punctures than for right-side punctures (Student t-test, p < 0.05). CONCLUSIONS: Real-time ultrasound monitoring is superior to blind techniques in cannulation of the internal jugular vein because of its ease, accuracy and safety. Sonographic real-time monitoring minimizes the impact of anatomic factors on success and complication rates. It is a safe and efficacious approach that should be preferred in the placement of central lines.
    [Abstract] [Full Text] [Related] [New Search]