These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: On-line urea kinetics in haemodiafiltration.
    Author: Santoro A, Tetta C, Mandolfo S, Arrigo S, Berti M, Colasanti G, D'Amico G, Imbasciati E, Mazzocchi C, Pacini G, Spongano M, Thomaseth K, Wratten ML, Zucchelli P.
    Journal: Nephrol Dial Transplant; 1996 Jun; 11(6):1084-92. PubMed ID: 8671973.
    Abstract:
    BACKGROUND: Calculation of Kt/V and assessment of nutrition have so far been dependent upon off-line urea measurements of blood or dialysate samples. Here we describe a biosensor for on-line urea measurement during haemodiafiltration. Methods. The biosensor consisted of a cartridge containing covalently linked urease placed between two conductivity cells. The biosensor was placed on the outlet line of a haemofilter in series with a dialyser in order to obtain an aliquot of plasma ultrafiltrate for on-line measurement of urea. RESULTS: Urea nitrogen concentrations were highly correlated to the difference (Delta) in conductivity measured by the two conductivity cells both in aqueous solutions (in-vitro studies, y=-6. 676+32.12x, R2=0.998, P<0.0001) and in ultrafiltrates (ex-vivo studies, y=-637+32.01x, R2=0.98, P<0.00001). Delta conductivity was highly reproducible (% variation: ).8-5.3%) and stable (maximal % variation at 150 mg/dl after 100 min. 0.9+/-0.3 vs initial values). The intradialytic plasma water urea profile was obtained in 10 haemodialysis patients. To study recirculation, the plasma water urea profile was analysed before and 3 min after stopping the dialysate flow. The pre- and post-stopped flow ratio (1.21+/-0.1, mean+/-1 SD) was superimposable to conventional blood sampling data (opposite arm venous arterial: 1.22+/-0.11) and allowed correction for recirculation. A novel approach to urea kinetic modelling was described and used to reliably project end-dialysis and post-dialysis rebound urea concentration as early as 90 min. Projected (29.2+/-10.4 g) or measured (29.8+/-10.5 g) net urea removal was highly correlated with the amount of urea collected in the total spent dialysate (29.7+/-10.6 g) (R2=0.99, R2=0.97 respectively). CONCLUSIONS: These results indicate that on-line, real-time analysis of urea kinetics may provide information on delivery of adequate dialysis in high-efficiency techniques.
    [Abstract] [Full Text] [Related] [New Search]