These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Technetium-99m-white blood cell-specific imaging agent developed from platelet factor 4 to detect infection. Author: Moyer BR, Vallabhajosula S, Lister-James J, Bush LR, Cyr JE, Snow DA, Bastidas D, Lipszyc H, Dean RT. Journal: J Nucl Med; 1996 Apr; 37(4):673-9. PubMed ID: 8691265. Abstract: UNLABELLED: We have developed a leukocyte-avid, 99mTc-labeled peptide (P483H) as a potential imaging agent for infection. P483H contains the heparin-binding region of platelet factor-4 (PF-4) and a lysine-rich sequence for rapid renal clearance. Technetium-99m-P483H was evaluated for its ability to selectively label white blood cells (WBCs) in vitro and to detect focal E. coli infections in rabbits. METHODS: Technetium-99m-P483H was incubated with citrated whole human blood, layered onto WBC isolation media and subjected to density gradient centrifugation to measure WBC-associated radioactivity. Indium-111-WBCs and 99mTc-gluceptate were used as controls. In the in vivo model, E. coli infected rabbits were imaged and necropsied 4 hr after administration of 99mTc-P483H. Infected and contralateral control muscles were evaluated for %ID, %ID/g, Imax (muscle sample showing the highest uptake, i.e., %ID/g) and Imax-to-blood and Imax-to-control muscle ratios. Indium-111-WBCs, 111In-DTPA, 131I-albumin (HSA), 99mTc-nanocolloid, 67Ga and 99mTc-gluceptate were evaluated as in vivo controls. RESULTS: Technetium-99m-P483H associated predominantly with WBCs in vitro, and 99m-Tc-P483H provided high contrast images of infection in vivo. In vitro, 73% of 99mTc-P483H radioactivity was associated with WBCs. Technetium-99m-P483H outperformed 111In-WBCs, 111In-DTPA, 131I-albumin, 99mTc-nanocolloid, 67Ga-citrate and 99mTc-gluceptate with an infection Imax average of 0.062 %ID/g (+/- 0.029; n = 48). Technetium-99m-P483H also outperformed all controls, including 111In-WBCs, 111In-DTPA, 131I-albumin, 99mTc-nanocolloid, 67Ga-citrate and 99mTc-gluceptate. The Imax-to-blood and Imax-to-control muscle ratios for 99mTc-P483H averaged 3.1 (+/- 2.4) and 26.8 (+/- 16.8), respectively, and again outperformed all controls. CONCLUSION: Technetium-99m-P483H associates predominantly with WBCs in vitro and identified focal infections in vivo within 4 hr versus conventional imaging agents. Additionally, the agent showed rapid blood clearance and exclusive renal excretion, which provides a clear abdominal field for imaging abdominal infections.[Abstract] [Full Text] [Related] [New Search]