These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Quantitative detection of human immunodeficiency virus (HIV) antigen by the Enzymun-Test: comparison with alternative assays and nucleic acid sequence-based amplification of HIV type 1 RNA.
    Author: Weber B, Melchior W, Preiser W, Hess G, Wahl M, Braner J, Doerr HW.
    Journal: J Clin Microbiol; 1996 Jun; 34(6):1440-7. PubMed ID: 8735095.
    Abstract:
    A new modular automated enzyme immunoassay (EIA) (Enzymun-Test HIV Ag: Boehringer Mannheim) for quantitative human immunodeficiency virus (HIV) antigen detection was evaluated by testing a panel of 1,506 serum samples, including seroconversions, dilution series, follow-up samples from patients under antiretroviral therapy, single serum specimens from HIV-seropositive individuals in different stages of infection, potentially cross-reactive samples, and sera from HIV-negative hospitalized patients. The Abbott HIV type 1 (HIV-1) antigen monoclonal antibody assay served as the reference assay, and nucleic acid sequence-based amplification (Organon Teknika) for quantitative amplification of HIV-1 RNA was used for follow-up of patients under antiretroviral chemotherapy. The Boehringer Mannheim and Abbott EIAs showed concordant results for the early detection of HIV antigen in all the seroconversion panels. The follow-up samples from 29 HIV-infected individuals under antiretroviral therapy gave divergent results between both antigen tests. For the detection of HIV antigen in single serum samples from HIV-infected patients in different stages of HIV infection, a higher number of positive samples was detected with the Abbott HIV-1 antigen monoclonal antibody assay in samples from patients in stages II and III of HIV infection. The Enzymun-Test detected three or more positive samples than did the Abbott assay among the samples of patients with AIDS. The concordance on a sample-to-sample basis between the Boehringer Mannheim and Abbott EIAs was 98.6%. The sensitivity of the Enzymun-Test in comparison to the reference assay was 97.2%; the specificity was 98.8%. Although no close correlation could be found between the amount of viral RNA in serum detected by nucleic acid sequence-based amplification and the concentration of HIV antigen, a high HIV-1 RNA copy number was mostly associated with high levels of HIV antigen. In conclusion, the Enzymun-Test permits accurate HIV antigen detection and offers, in contrast to previous assays, the possibility of completely automated detection.
    [Abstract] [Full Text] [Related] [New Search]