These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes.
    Author: Dasgupta A, Blackwell W, Bard D.
    Journal: Ther Drug Monit; 1996 Jun; 18(3):306-9. PubMed ID: 8738774.
    Abstract:
    Recently Becton-Dickinson marketed a plastic serum-separator tube that uses the same serum-separator gel as the glass tubes. We studied the stability of therapeutic drugs stored in plastic tubes by comparing it with the stability of drugs stored in glass serum-separator tubes and plain red-top glass tubes. We observed no absorption of caffeine, primidone, N-acetylprocainamide, procainamide, theophylline, tobramycin, ethosuximide, acetaminophen, amikacin, valproic acid, methotrexate, salicylate, and cyclosporine in either plastic or glass serum-separator tubes. On the other hand, concentrations of lidocaine, quinidine, phenobarbital, and phenytoin were reduced after storing in both plastic and glass serum-separator tubes, especially with prolonged storage and small sample volume. The reduction in concentrations were due to slow absorption of those drugs by serum-separator gel.
    [Abstract] [Full Text] [Related] [New Search]