These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Simple clinical method of average intima-media thickness measurement in the common carotid artery. Author: Csányi A, Egervári A. Journal: Vasa; 1996; 25(3):242-8. PubMed ID: 8795305. Abstract: The wall thickness of the atherosclerotic common carotid artery may be quantitatively assessed by measuring of the intima-media thickness with high resolution B-mode ultrasonography. The reliability and reproducibility of a simple non-invasive planimetric method has been assessed. The interobserver, intraobserver, interreading and cardiac cycle dependent variabilities of intima-media thickness measurements in 150 randomly selected patients were evaluated. The mean absolute differences were 0.078 +/- 0.097 mm (interobserver), 0.064 +/- 0.052 and 0.048 +/- 0.05 mm (intraobserver), 0.016 +/- 0.037 and 0.018 +/- 0.038 (interreading), 0.072 +/- 0.076 and 0.054 +/- 0.061 (cardiac cycle dependent, pre-T and R-triggered). The results were satisfactory with coefficients of variation 13.1% (interobserver), 5.7-6% (intraobserver), 4-4.9% (interreading) and 7-8.5% (cardiac cycle dependent). This simple ultrasonic technique yielded highly reproducible measures of common carotid artery average intimal-medial thickness on the far wall and it appeared to be a reliable method for clinical investigations.[Abstract] [Full Text] [Related] [New Search]