These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of ampicillin residues in milk by ion-pair reversed phase high performance liquid chromatography after precolumn derivatization.
    Author: Verdon E, Couedor P.
    Journal: J Pharm Biomed Anal; 1996 Jun; 14(8-10):1201-7. PubMed ID: 8818034.
    Abstract:
    A high performance liquid chromatography method has been developed for the determination of ampicillin residues in milk. The method involves extraction of ampicillin from milk with trichloroacetic acid solution followed by concentration on a conditioned C18 solid phase extraction column, acetylation with acetic anhydride in aqueous solution (pH 8.0) at ambient temperature for 3 min followed by reaction with 2 M 1, 2, 4-triazole and 10(-2) M mercury (II) chloride solution (pH 9.0) at 65 degrees C for 10 min. The resulting product is eluted on a C18 column with a mobile phase containing phosphate buffer (pH 6.5; 0.1 M), the ion-pairing agent tetrabutylammonium hydrogenosulphate, acetonitrile and methanol. The detection limit of the method is 3 ng ml-1 in milk.
    [Abstract] [Full Text] [Related] [New Search]