These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Femoral component fixation with and without intramedullary plug. A 6-year follow-up. Author: Suominen S, Antti-Poika I, Tallroth K, Santavirta S, Voutilainen P, Lindholm TS. Journal: Arch Orthop Trauma Surg; 1996; 115(5):276-9. PubMed ID: 8836461. Abstract: A total of 113 patients underwent a cemented total hip replacement (THR) operation involving femoral component fixation either without the use of a distal intramedullary plug (n = 57, group 1) or with the plug (n = 56, group 2). We studied the femoral component fixation radiographically at on average 6 years after THR. The cement coating was assessed as technically good in 86% and 95% of groups 1 and 2, respectively. There was radiographically diagnosable loosening of the femoral component at the follow-up in 25 cases in which stems were inserted without the intramedullary plug, and in 6 cases in those with the plug (P < 0.0008), and the mean subsidence of the femoral component was 5 mm in group 1 and 1.5 mm (P < 0.0003) in group 2, respectively. Osteolytic changes around the femoral component were noticed in both groups in equal numbers and with no statistical difference. The use of a distal intramedullary plug in the cementation of the femoral stem results in a better cement coating, reduces femoral component subsidence and ameliorates the loosening rates.[Abstract] [Full Text] [Related] [New Search]