Title: Ocular characteristics associated with rigid gas-permeable lens adherence. Author: Swarbrick HA, Holden BA. Journal: Optom Vis Sci; 1996 Jul; 73(7):473-81. PubMed ID: 8843127. Abstract: PURPOSE: Rigid gas-permeable (RGP) lens adherence after overnight lens wear is clearly a patient-dependent phenomenon. However, no previous study has attempted to determine whether specific ocular characteristics are associated with an increased frequency of lens adherence. METHOD: In this study, clinically applicable tests were used to measure a range of ocular characteristics, including central and peripheral corneal curvature, tear film status, eyelid characteristics, central corneal thickness, and ocular rigidity in a group of 22 young adult subjects for whom reliable estimates for frequency of overnight RGP lens adherence had been obtained from earlier studies. RESULTS: Linear discriminant analysis revealed that a higher frequency of lens adherence was associated with lower ocular rigidity, thinner central corneas, greater eyelid tension, and lower amounts of corneal astigmatism. CONCLUSIONS: These findings suggest a clinical approach for identifying patients who may develop clinically significant lens adherence during RGP extended wear, and also provide support for the "thin film adherence" theory of RGP lens adherence.[Abstract] [Full Text] [Related] [New Search]