Title: High-performance liquid chromatographic determination of the enantiomers of cyclophosphamide in serum. Author: Corlett SA, Chrystyn H. Journal: J Chromatogr B Biomed Appl; 1996 Jul 12; 682(2):337-42. PubMed ID: 8844428. Abstract: A high-performance liquid chromatographic (HPLC) achiral-chiral coupled assay to measure the serum concentration of the enantiomers of cyclophosphamide is described. The R- and S-enantiomers of cyclophosphamide were quantified using a 5-cm-long C1 Spherisorb 5-microns column, with switching of the eluent containing racemic cyclophosphamide onto a 10-cm-long alpha 1 acid glycoprotein column. The limit of determination was 1.25 mg l-1 for each enantiomer and the ratio of the enantiomers over the range 2.5 to 100 mg l-1 was I. Serum enantiomer concentrations in blood samples taken from patients receiving 0.30 to 0.75 gm-2 of intravenous racemic cyclophosphamide could be measured at least three half-lives post dose. In six patients no significant difference in the clearance of R- and S-cyclophosphamide was found.[Abstract] [Full Text] [Related] [New Search]