These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Evolution of early TIMI 2 flow after thrombolysis for acute myocardial infarction. GUSTO-1 Angiographic Investigators. Author: Reiner JS, Lundergan CF, Fung A, Coyne K, Cho S, Israel N, Kazmierski J, Pilcher G, Smith J, Rohrbeck S, Thompson M, Van de Werf F, Ross AM. Journal: Circulation; 1996 Nov 15; 94(10):2441-6. PubMed ID: 8921786. Abstract: BACKGROUND: Patients with early Thrombolysis in Myocardial Infarction (TIMI) grade 2 flow after thrombolysis appear to have outcomes similar to thrombolytic failures. To evaluate the origin and evolution of early TIMI 2 flow, we examined early and late angiographic and ventriculographic data from the Global Utilization of Streptokinase and TPA for Occluded Arteries (GUSTO-1) angiographic study. METHODS AND RESULTS: Of the 914 patients with both 90-minute and 5- to 7-day catheterizations, 278 patients had TIMI grade 2 flow at 90 minutes. At follow-up, 188 (67%) had improved to TIMI grade 3 flow. At 90 minutes, patients with TIMI grade 2 flow had greater infarct vessel narrowing and a significantly greater incidence of thrombus than patients with TIMI grade 3 flow. At the 5- to 7-day follow-up, patients whose flow had improved from TIMI grade 2 at 90 minutes to grade 3 flow at follow-up had larger-caliber vessels (minimum luminal diameter, 0.99 +/- 0.47 versus 0.84 +/- 0.48 mm; P = .03) and a lower incidence of visible thrombus (26% versus 38%, P = .04) than those with persistent TIMI grade 2 flow. These patients also had a higher mean ejection fraction (57.5 +/- 14.1% versus 52.8 +/- 12.9%, P = .02) and better infarct zone wall motion (-2.1 +/- 1.5 versus -2.6 +/- 1.3 SD per chord, P = .01) at the 5- to 7-day follow-up. Patients in whom flow improved from TIMI grade 2 at 90 minutes to TIMI grade 3 by 5 to 7 days had significantly better left ventricular function than patients with persistent TIMI grade 0, 1, or 2 flow and constituted a group whose left ventricular function was intermediate between those who had no reperfusion (TIMI grades 0 and 1) and those whose reperfusion was complete (TIMI grade 3). CONCLUSIONS: These data suggest that incomplete clot lysis plays a significant role in the pathogenesis of TIMI grade 2 flow. Furthermore, early TIMI grade 2 flow may be sufficient to provide prolonged myocyte viability, which will further recover if flow normalizes.[Abstract] [Full Text] [Related] [New Search]