These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Complications following metal removal: a follow-up of surgically treated forearm fractures. Author: Chia J, Soh CR, Wong HP, Low YP. Journal: Singapore Med J; 1996 Jun; 37(3):268-9. PubMed ID: 8942225. Abstract: We undertook a retrospective study of 82 patients with 128 diaphyseal fractures of the forearm who had been operated at our institution for their initial injury and subsequently had implant removal when the fractures had healed. The majority of the patients (97.5%) had no major complications after the removal of implants but 2 patients sustained a re-fracture of the same bone within 6 months after plate removal. Both patients had suffered from open fracture at the initial injury and sustained re-fracture in the original fracture site after implant removal. These fractures were both treated conservatively in a cast and united without further problems. Another 20 patients (24.4%) had minor complications ranging from mild superficial wound infection to nerve injury.[Abstract] [Full Text] [Related] [New Search]