These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Stentless aortic valve replacement with the biocor prosthesis: indications and outcome. Author: Achtelik M, Pethig K, Schäfers HJ, Borst HG. Journal: J Heart Valve Dis; 1996 Nov; 5 Suppl 3():S314-6. PubMed ID: 8953460. Abstract: BACKGROUND AND AIMS OF THE STUDY: Due to improved hemodynamic properties stentless bioprostheses represent a new therapeutic option in the surgical treatment of aortic valve disease. MATERIALS AND METHODS: Between February 1993 and June 1995 22 patients with a small aortic root regarded as suboptimal for a stented bioprosthesis (diameter < or = 23 mm, mean 21.6 +/- 1.9 mm) underwent aortic valve replacement with a Biocor stentless prosthesis. Mean age was 63.9 +/- 15.4 years (17-85 years). Valve size ranged from 21 to 27 mm (mean 25 mm) and exceeded the root diameter by 4 mm. As compared to a control group of patients with root enlargement (n = 10) total bypass time and cross-clamp time in the stentless group were significantly shorter (83.3 +/- 12.7 and 60.9 +/- 9.2 min versus 95.8 +/- 27.1 and 69.5 +/- 16.5 min, p = 0.054 and p < 0.05), respectively. RESULTS: Three patients died postoperatively unrelated to the choice of valve. There were no late deaths. No thromboembolic or bleeding events were observed. Follow up data are available over a period of 1-25 months (mean 12.5 months, median 16 months). Echocardiographic evaluation revealed no aortic regurgitation; mean valve gradients were 9.9 +/- 4.1 mmHg (peak 19.2 +/- 6.0 mmHg). For specific root diameters these gradients were compared to established data for Hancock bioprostheses demonstrating significant differences in transvalvular gradients between the two valve designs for given root diameters. Unloading the left ventricle resulted in regression of left ventricular hypertrophy (decrease in wall thickness from 13.6 +/- 1.7 mm to 11.2 +/- 2.0 mm). Exercise capacity improved from NYHA III-IV preoperative to I-II postoperative. CONCLUSIONS: In patients with a small aortic root stentless valves represent a new option. Compared to root enlargement with standard bioprosthesis myocardial ischemia is shorter and implantation of larger valve sizes results in superior hemodynamics.[Abstract] [Full Text] [Related] [New Search]