These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Mosaic single plasma sample method for measuring glomerular filtration rate. Author: Kim CK, Religioso DG. Journal: Nucl Med Commun; 1996 Nov; 17(11):952-6. PubMed ID: 8971866. Abstract: Seven single plasma sample methods for measuring glomerular filtration rate (GFR) were evaluated. When compared with GFRs calculated from a slope/intercept method proposed by Russell et al. [6] (using 1 h and 3 h plasma samples) as a reference standard, each single-sample method produced better results in different ranges of GFR (3 h plasma sample was used for all seven single-sample methods). Combining the best single-sample method in each range (mosaic) resulted in a regression line of y = 0.98x + 1.0, with a correlation coefficient of 0.980 and a standard error of estimate of 6.5 ml min-1 in 294 samples. This mosaic method yielded more accurate and realistic GFR values than any other individual single-sample method.[Abstract] [Full Text] [Related] [New Search]