These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Dentine bond of light-activated glass-ionomer liner/bases.
    Author: Aboush YE.
    Journal: J Ir Dent Assoc; 1994; 40(3):63-5. PubMed ID: 8975046.
    Abstract:
    This in vitro study comparatively assessed the magnitude and durability of the bonds to dentine of three glass-ionomer liner/bases, BaseLine VLC, Vitrebond and XR Ionomer. Shear bond strengths to human dentine were measured after 24 h. storage in water at 37 degrees C and after 5,000 continuous thermocycles between 5 degrees C and 55 degrees C. The BaseLine VLC material failed to achieve any measurable bond. The mean bond strength values of Vitrebond after 24 h. storage in water at 37 degrees C and after thermocycling were significantly higher (p < 0.05) than those of XR Ionomer. Both Vitrebond and XR Ionomer exhibited a drop in their bond strengths after thermocycling but this was statistically significant only in the case of XR Ionomer. These findings indicate that Vitrebond exhibits a more reliable bond to dentine compared to those of BaseLine VLC and XR Ionomer.
    [Abstract] [Full Text] [Related] [New Search]