These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Evidence that atrial natriuretic peptide tissue extraction is not changed by large increases in its plasma levels induced by pacing in humans.
    Author: Iervasi G, Clerico A, Pilo A, Vitek F, Berti S, Palmieri C, Ravani M, Sabatino L, Manfredi C, Del Chicca MG, Biagini A, Donato L.
    Journal: J Clin Endocrinol Metab; 1997 Mar; 82(3):884-8. PubMed ID: 9062501.
    Abstract:
    Atrial natiurectic peptide (ANP) is a cardiac hormone with a very short plasma half-life, which plays an important role in a variety of clinical conditions associated with an increase in pressure and/or volume overload on the heart. The MCR of the hormone is considered to represent a stable parameter, reflecting the uptake and degradation rate of ANP by the periphery, only scarcely affected by rapid oscillations of circulating levels. To evaluate the extent to which MCR is affected by rapid and large variations of circulating levels of the hormone, we measured MCR in five patients with different degrees of myocardial function (from normal to severely impaired), in whom changes in ANP levels were induced by atrial and/or ventricular pacing. Cardiac output was simultaneously measured by thermodilution to calculate whole body extraction of ANP. During constant i.v. infusion of [125I]ANP, the hormone MCR was determined both under basal conditions (at tracer equilibration, 20-30 min after the start of infusion) and during atrial and ventricular pacing. Pacing maneuvers, begun 50 min after the start of infusion, induced a marked and rapid increase in endogenous plasma ANP values in all patients (on the average, 3,7-fold compared to basal values; range, 1.8-5.68), whereas corresponding values of [125I]ANP only minimally changed. The MCR of ANP (3.62 +/- 1.06 L/min, mean +/- SD) slightly decreased (by repeated measures ANOVA, P = 0.0458) during atrial and ventricular pacing procedures (3.35 +/- 1.03 and 3.15 +/- 0.74 L/min, respectively), reaching a mean value of 88.7 +/- 9.0% compared to basal. The small decrease in MCR could be almost completely ascribed to hemodynamic factors; indeed, basal cardiac output (5.76 +/- 1.70 L/min) was found, on the average, to be slightly decreased during atrial and ventricular pacing (5.28 +/- 1.46 and 5.16 +/- 1.33 L/min, respectively), and so whole body extraction of the hormone, measured before pacing (50.0 +/- 12%), remains stable throughout the study period (50.4 +/- 10.6% and 49.6 +/- 10% during atrial and ventricular pacing, respectively). Our findings demonstrate that degradative mechanisms involved in ANP clearance are not saturable at least for acute elevations of ANP plasma levels up to 3-5 times the basal level.
    [Abstract] [Full Text] [Related] [New Search]