These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Detection of seizures from small samples using nonlinear dynamic system theory.
    Author: Yaylali I, Koçak H, Jayakar P.
    Journal: IEEE Trans Biomed Eng; 1996 Jul; 43(7):743-51. PubMed ID: 9216146.
    Abstract:
    The electroencephalogram (EEG), like many other biological phenomena, is quite likely governed by nonlinear dynamics. Certain characteristics of the underlying dynamics have recently been quantified by computing the correlation dimensions (D2) of EEG time series data. In this paper, D2 of the unbiased autocovariance function of the scalp EEG data was used to detect electrographic seizure activity. Digital EEG data were acquired at a sampling rate of 200 Hz per channel and organized in continuous frames (duration 2.56 s, 512 data points). To increase the reliability of D2 computations with short duration data, raw EEG data were initially simplified using unbiased autocovariance analysis to highlight the periodic activity that is present during seizures. The D2 computation was then performed from the unbiased autocovariance function of each channel using the Grassberger-Procaccia method with Theiler's box-assisted correlation algorithm. Even with short duration data, this preprocessing proved to be computationally robust and displayed no significant sensitivity to implementation details such as the choices of embedding dimension and box size. The system successfully identified various types of seizures in clinical studies.
    [Abstract] [Full Text] [Related] [New Search]