These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Replacement of the aortic root with woven and knitted Dacron composite graft]. Author: Mashiko K, Ishii S, Naganuma H, Yoshida S, Seo A, Sakamoto H, Mikawa H, Okuyama H. Journal: Kyobu Geka; 1997 Jul; 50(7):540-3. PubMed ID: 9223857. Abstract: Some of the patients with annuloaortic ectasia or Stanford type A require aortic root replacement. If conventional Bentall procedure is employed in such cases, aortic root will become a cylindrical shape totally lacking sinus of Valsalva because the procedure utilizes a straight tube. The sinuses of Valsalva support an important role in opening and closing the valvar leaflets, and opening of the coronary arteries, together with the interleaflet triangles and the sinutubular junction. In this study, we performed aortic root replacement with composite graft which consisted of two types of graft including 30 mm Knitted Dacron Graft (Gelsoft) with different dilation rates and 30 mm Woven Dacron Graft (Hemashield) as well as bioprosthesis (27 mm Carpentier-Edwards), in order to reconstruct sinus of Valsalva. Post-operative angiography revealed an excellent diastolic coronary flow, as evidenced by proximal Knitted graft of 37 mm in diameter, distal Woven graft of 30.3 mm in diameter and Doppler flow DSVR (Diastolic/Systolic Velocity Ration) of 2.2 measured at the left coronary orifice. Since it is difficult to obtain homograft at present, this procedure would be worth trying during aortic root replacement.[Abstract] [Full Text] [Related] [New Search]