These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Effect of independent changes in mixed-venous PCO2 or PO2 on cardiac output in anesthetized sheep. Author: Shanley CJ, Shah NL, Overbeck MC, Kulkarni NB, Bartlett RH. Journal: J Surg Res; 1997 Aug; 71(2):107-16. PubMed ID: 9299277. Abstract: To determine whether changes mixed-venous PCO2 or PO2 affect cardiac output independent of changes in arterial blood gases, we used extracorporeal gas exchange to increase mixed-venous PCO2 or decrease mixed-venous PO2 in adult sheep. Sheep were anesthetized, mechanically ventilated, and connected to a veno-venous extracorporeal circuit. The circuit included a gas exchanger which was used to increase mixed-venous PCO2 or decrease mixed-venous PO2; the native lungs were ventilated to maintain arterial PCO2 and PO2 at control levels. When mixed-venous PCO2 was increased by 32% above control levels for a period of 60 min, cardiac output increased significantly to 28% above control levels. Cervical vagotomy abolished this response. In contrast, decreasing mixed-venous PO2 by 29% did not increase cardiac output. These results demonstrate that increasing mixed-venous PCO2 can increase cardiac output independent of changes in arterial blood gases and that intact vagus nerves are necessary for this response to occur.[Abstract] [Full Text] [Related] [New Search]