These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Mandibular fracture after endosseous implant placement in conjunction with inferior alveolar nerve transposition: a patient treatment report.
    Author: Kan JY, Lozada JL, Boyne PJ, Goodacre CJ, Rungcharassaeng K.
    Journal: Int J Oral Maxillofac Implants; 1997; 12(5):655-9. PubMed ID: 9337027.
    Abstract:
    A patient with a severely atrophic right posterior mandible had three endosseous implants placed in conjunction with transposition of the inferior alveolar nerve. Three weeks following implant placement surgery, the patient experienced a spontaneous fracture of the mandible involving the two anterior implants. The two implants were removed, and the fracture was treated with open reduction and fixation with titanium mesh. The fracture healed, and the posterior implant integrated. This report suggests that the buccolingual and superior-inferior position of the mandibular canal can increase the possibility of mandibular fracture by increasing the size of the buccal cortical plate that is removed to expose the nerve during surgery.
    [Abstract] [Full Text] [Related] [New Search]