These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Nebulized interleukin 2 liposomes: aerosol characteristics and biodistribution. Author: Khanna C, Waldrep JC, Anderson PM, Weischelbaum RW, Hasz DE, Katsanis E, Klausner JS. Journal: J Pharm Pharmacol; 1997 Oct; 49(10):960-71. PubMed ID: 9364403. Abstract: Although interleukin 2 (IL-2) has been associated with modest anti-tumour responses in man, treatment-related toxicity has limited its widespread use. The local delivery of liposomal formulations of interleukin 2 to the lung as aerosols has been demonstrated to be non-toxic, biologically active, and associated with regression of spontaneous pulmonary metastases in dogs. This study was undertaken to evaluate the physical and biological characteristics of nebulized interleukin 2 liposomes. The aerosol droplet size distribution and the physical stability of interleukin 2 liposomes were examined in-vitro using an Andersen cascade impactor and studies of liposome entrapment of interleukin 2 before and after nebulization. The biological stability of interleukin 2 liposomes after nebulization was demonstrated using the CTLL-2 bioassay for interleukin 2. In-vivo studies of pulmonary biodistribution and clearance of inhaled technetium (99mTc)-labelled interleukin 2 liposomes were undertaken in a normal dog. Aerosols of free interleukin 2 and of interleukin 2 liposomes were compared in both in-vitro and in-vivo experiments. The mass median aerodynamic diameter (MMAD) and geometric standard deviation (GSD) of interleukin 2 liposomes were 1.98 microns and 2.02, respectively. Independent analysis of aerosol particle-size distribution using the constitutive components of the interleukin 2 liposomes (interleukin 2: lipid:HSA) demonstrated a close correlation of size distributions (r = 0.9445; P < 0.001). The entrapment of interleukin 2 in liposomes was 93 +/- 4.3% before nebulization and 90 +/- 8.9% after. After delivery to an anaesthetized dog, interleukin 2 liposome aerosols were deposited evenly throughout the lung (mean +/- s.d. central lung-to-peripheral lung deposition was 1.12 +/- 0.03). After approximately 24 h inhalation, interleukin 2 liposomes were retained within the lung and were taken up in part by the spleen. The results of this study are indicative of the stability of this interleukin 2 liposome formulation to nebulization. Such nebulization might be an attractive immunotherapeutic strategy for treatment of pulmonary metastases and primary lung cancers.[Abstract] [Full Text] [Related] [New Search]