  • Title: Multivessel system for cold-vapor mercury generation. Determination of mercury in hair and fish.
    Author: Boaventura GR, Barbosa AC, East GA.
    Journal: Biol Trace Elem Res; 1997; 60(1-2):153-61. PubMed ID: 9404685.
    Abstract:
    A multivessel system for the determination of mercury (Hg) by cold-vapor atomic absorption spectrometry (CV-AAS) and inductively coupled plasma atomic emission spectrometry (ICP-AES) was developed. The performance of the proposed device was tested by determining total Hg in quality-control samples of hair and fishes following acid digestion. Application of the apparatus to the determination of Hg by CV-AAS following alkaline digestion was studied as well. The detection limit obtained for CV-AAS was 0.11 ng/mL and for ICP-AES 1.39 ng/mL. The results show that the system is appropriate to be used in techniques involving cold-vapor generation of Hg.