These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Revision of reversed infrainguinal bypass grafts without preoperative arteriography. Author: Treiman GS, Lawrence PF, Galt SW, Kraiss LW. Journal: J Vasc Surg; 1997 Dec; 26(6):1020-8. PubMed ID: 9423718. Abstract: PURPOSE: To determine whether graft revision on the basis of a duplex scan alone without an arteriogram is effective in identifying graft stenosis and allowing for repair to preserve bypass graft patency. METHODS: From 1994 to 1997, all patients in whom infrainguinal grafts were placed at a University-affiliated teaching hospital were entered into a prospective protocol using duplex scanning to detect stenotic lesions. Studies were performed after the operation, at 1 month, at 3 months, and every 3 months thereafter. All grafts were composed of reversed autogenous vein and were placed subcutaneously to allow for easier monitoring and correction. Patients who had failing grafts underwent operative correction without preoperative arteriography. RESULTS: During this interval, 48 lesions in 31 grafts were repaired. The indication for repair was a velocity ratio greater than 2.5 in all patients and greater than 3.0 for 43 lesions. Forty-four lesions had a peak systolic velocity greater than 250 cm/sec. Twenty-nine lesions reduced the distal graft velocity to less than 45 cm/sec. Sixteen lesions involved the proximal anastomosis, 26 the body of the graft, three the distal anastomosis, two involved inflow arteries, and one affected the outflow vessel. Repair included patch angioplasty for 39 lesions, resection with interposition graft for five, a proximal jump graft for three, and a distal extension graft for one. The severity and location of the stenosis was confirmed at operation in all cases. Twenty-eight of the 31 patients (90%) are currently alive, and follow-up on these patients has ranged from 5 to 36 months (mean, 19 months). Twenty-nine of the 31 grafts (94%) remained patent, with a 92% patency rate by life table analysis at 3 years. Follow-up duplex scans found improvement in the ankle-brachial index (mean increase, 0.33) and distal graft velocity (mean increase, 43 cm/sec) in all patients. After repair, 27 patients had a distal graft velocity greater than 45 cm/sec and no patient had a velocity ratio greater than 1.5. Complications included wound infection in two patients and bleeding that required reoperation in one. All symptomatic patients had clinical improvement, and none required early reexploration for residual stenosis. CONCLUSIONS: Graft repair may be safely performed on the basis of duplex scanning alone with preservation of bypass patency and correction of hemodynamic deterioration. Duplex scanning can detect inflow or outflow disease in addition to intrinsic graft stenoses and can identify sequential lesions, eliminating the need for, expense of, and risk of arteriography.[Abstract] [Full Text] [Related] [New Search]