These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: 14CO2-in-air sampling with passive diffusion samplers. Author: Wood MJ, Surette RA, Mohindra JK, Patterson JG. Journal: Health Phys; 1998 Feb; 74(2):253-8. PubMed ID: 9450595. Abstract: Passive diffusion samplers designed for measuring HTO-in-air have been evaluated for measuring 14CO2-in-air. Controlled exposures to HTO-in-air, 14CO2-in-air, and a combination of the two gases were carried out. The sampling rate of the 14CO2-in-air was found to be approximately 0.7 that of HTO-in-air. This value is consistent with the calculated relative sampling rates based on the diffusion coefficients of the gases. Passive diffusion samplers currently used for sampling HTO-in-air at CANDU facilities have been shown to be suitable for also measuring 14CO2-in-air and HTO-in-air simultaneously when prepared with the appropriate sampling solution.[Abstract] [Full Text] [Related] [New Search]