These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [5-year results of dia-/supracondylar femoral fractures, managed with the dynamic condylar screw]. Author: Ketterl R, Köstler W, Wittwer W, Stübinger B. Journal: Zentralbl Chir; 1997; 122(11):1033-9. PubMed ID: 9480597. Abstract: In 118 patients with intra- and extraarticular distal femoral fractures we used open reduction and internal fixation with a dynamic condylar screw. We recorded general implant related complications in a very low percentage of patients. In evaluation of the long-term results in eighty one patients after follow-up of more than five years we found occasional pain in eighteen patients and frequent pain in two patients. 70% of the patients presented with free range of motion in knee joint. Only five patients had a clinically important malunion of greater than five degrees. We found malrotation of greater than ten degrees in four patients. 90% of patients were found to have a stable knee joint. The functional result according to Neer was excellent in more then 50 percent and satisfying in 40 percent of the patients. Only in 5 patients the result was determined as unsatisfying or as a failure. No arthrotic changes were found in the femoro-patellar and femoro-tibial joint in about 75 percent of the cases. Grade 2 changes were found in 15 percent in the femoro-patellar joint and in 18 percent in the femoro-tibial joint. Grade 3 arthrotic changes were seen even in less than 10 percent in both parts of the knee joint.[Abstract] [Full Text] [Related] [New Search]