These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Cobalt-chromium-titanium alloy for removable partial dentures. Author: Iwama CY, Preston JD. Journal: Int J Prosthodont; 1997; 10(4):309-17. PubMed ID: 9484040. Abstract: Pure elemental titanium was alloyed with cobalt and chromium in dilutions of 4%, 5%, and 6% to evaluate the suitability of the resulting alloy for removable partial denture frameworks. The physical properties of the Co-Cr-Ti alloy were compared to the properties of a commercial pure titanium and Vitallium. Clasp replicas were cast in Co-Cr-Ti and Vitallium and subjected to cyclic deflection. Representative specimens from the fatigue failure tests were then evaluated using scanning electron microscopy and analyzed for elemental content. The 5% titanium dilution of cobalt-chromium proved to have the best physical properties and was used for comparison with the pure titanium and Vitallium. The Co-Cr-5% Ti had significantly better physical properties than pure titanium and a greater flexure fatigue limit than the Vitallium alloy.[Abstract] [Full Text] [Related] [New Search]