These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Lack of promoting effects of the electromagnetic near-field used for cellular phones (929.2 MHz) on rat liver carcinogenesis in a medium-term liver bioassay.
    Author: Imaida K, Taki M, Yamaguchi T, Ito T, Watanabe S, Wake K, Aimoto A, Kamimura Y, Ito N, Shirai T.
    Journal: Carcinogenesis; 1998 Feb; 19(2):311-4. PubMed ID: 9498282.
    Abstract:
    The possible cancer promotion potential of local exposure to a pulse modulated 929.2 MHz electromagnetic near-field on chemically-initiated rat liver carcinogenesis was investigated employing a medium-term bioassay. A 929.2-MHz electromagnetic near-field of time division multiple access (TDMA) signal for PDC (Personal Digital Cellular, Japanese cellular telephone standard) system was directed to rats through a quarter-wavelength monopole antenna. Maximum local specific absorption rates (SARs) on temporal average were 7.2-6.6 W/kg within the whole body and 2.0-1.7 W/kg within the liver, which was the target organ. The whole-body average SARs on temporal average were 0.80-0.58 W/kg. Temporal peak SARs had three times these values due to the duty ratio of the PDC signal. Exposure was for 90 min a day, 5 days a week, over 6 weeks. The exposure apparatus was specially designed for this experiment, to allow exposure of the lateral mid-section of the rat body to the electromagnetic near-field. Male F344 rats, 6 week-old, were initially (at week 0) given a single dose of diethylnitrosamine (DEN, 200 mg/kg body wt, i.p.). At 2 weeks later, exposure (48 rats) or sham-exposure (48 rats) was started. The exposure of electromagnetic near-fields was performed using the exposure apparatus mentioned above. At week 3, all rats were subjected to a 2/3 partial hepatectomy. At week 8 (i.e. after 6 weeks exposure or sham-exposure), the experiment was terminated and all rats were killed. Carcinogenic potential was scored by comparing the numbers and areas of the induced glutathione S-transferase placental form (GST-P) positive foci in the livers of the exposed and sham-exposed rats. A further group of 24 animals, given only DEN and partial hepatectomy, served as the controls. The numbers (no./cm2) of GST-P positive foci were 4.61 +/- 1.77, 5.21 +/- 1.92 (P < 0.05, versus control) and 4.09 +/- 1.47 and the areas (mm2/cm2) were 0.30 +/- 0.16, 0.36 +/- 0.21 and 0.28 +/- 0.15, for the exposed, sham-exposed and control groups, respectively. There were no significant differences between the exposed and sham-exposed groups. These findings clearly indicated that local body exposure to a 929.2-MHz field, modulated in a PDC waveform, has no significant effect on rat liver carcinogenesis under the experimental conditions employed.
    [Abstract] [Full Text] [Related] [New Search]