These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Quantitative determination of the beta-blocker labetalol in pharmaceuticals and human urine by high-performance liquid chromatography with amperometric detection. Author: Ceniceros C, Maguregui MI, Jiménez RM, Alonso RM. Journal: J Chromatogr B Biomed Sci Appl; 1998 Jan 23; 705(1):97-103. PubMed ID: 9498675. Abstract: A rapid and simple high-performance liquid chromatographic (HPLC) method with amperometric detection has been developed for the quantitation of labetalol in urine. The chromatography was performed at 30 degrees C using a reversed-phase column with a base deactivated silica stationary support and an alkylamide bonded phase (Supelcosil ABZ+Plus). A 5 mM acetate buffer (pH 4.5)-acetonitrile (70:30, v/v) mixture was employed as the mobile phase, pumped at a flow-rate of 1 ml/min. Sample preparation was carried out using a simple solid-phase extraction (SPE) procedure, and recoveries higher than 85% were achieved. The method was found to be accurate, precise (R.S.D lower than 8%), and sensitive enough (experimental quantitation limit of 20 ng/ml, detection limit 10 ng/ml) to be applied to doping analysis and pharmacokinetic studies in human urine. The method was applied to the determination of labetalol in pharmaceutical formulations and urine samples obtained from a healthy volunteer after the ingestion of a therapeutic dose of the drug, and the results obtained were in agreement with the pharmacokinetic data.[Abstract] [Full Text] [Related] [New Search]