These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Gas phase separation during decompression in man: ultrasound monitoring.
    Author: Neuman TS, Hall DA, Linaweaver PG.
    Journal: Undersea Biomed Res; 1976 Jun; 3(2):121-30. PubMed ID: 951822.
    Abstract:
    During two dive series, one to 132 fsw and one to 210 fsw, Doppler ultrasonic bubble detectors were used to monitor venous gas bubbles in divers during decompression and for 30 min thereafter. Various decompression schedules were used. Bubble scores were evaluated by independent listerners to tape recordings in a blind manner. A significant increase in bubble scores throughout the stages of decompression and postdecompression was demonstrated as well as a statistically significant relationship between bubble score and decompression sickness. A reduction in mean bubble score was found in divers who made an additional deep decompression stop that was unrelated to the extension of the decompression time. The implications of these findings are discussed.
    [Abstract] [Full Text] [Related] [New Search]