These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Metastatic axillary lymph node technetium-99m-MIBI imaging in primary breast cancer.
    Author: Taillefer R, Robidoux A, Turpin S, Lambert R, Cantin J, Léveillé J.
    Journal: J Nucl Med; 1998 Mar; 39(3):459-64. PubMed ID: 9529292.
    Abstract:
    UNLABELLED: Technetium-99m-MIBI scintimammography has been shown to be useful in the detection of primary breast cancer. The purpose of this study was to evaluate the potential role of scintimammography in detecting axillary lymph node involvement in patients undergoing scintimammography to detect primary breast cancer. METHODS: A group of 100 women with breast cancer who were scheduled for a Level I-II axillary dissection were prospectively studied. Scintimammography was performed in all patients before histopathologic confirmation of breast cancer. Two lateral (prone imaging) views and one anterior (supine) planar thoracic view were obtained 10-15 min after the injection of 25-30 mCi 99mTc-MIBI (10 min/view) by using a special breast positioning device (foam cushion) placed over the imaging table. Both of the axilla were included in the field-of-view. Two experienced blinded observers reviewed all cases both from films and from the computer screen with contrast adjustment when needed. The site of intravenous injection of 99mTc-MIBI was known to the interpreters in order to avoid reading any false-positive uptake in the axilla ipsilateral to the injection site. RESULTS: A total of 52 patients had no axillary lymph node involvement (611 negative nodes) while 48 patients had at least one axillary lymph node with metastatic involvement (180/502 positive nodes). The sensitivity of scintimammography in detecting metastatic axillary lymph node involvement was 79.2% (38/48), and the specificity was 84.6% (44/52). The positive and the negative predictive values were 82.6% (38/46) and 81.5% (44/54), respectively. CONCLUSION: This study shows that scintimammography has good diagnostic accuracy for detecting axillary lymph node involvement in patients with breast cancer. This information should be added to the result of standard scintimammography, which requires very minor modifications in order to simultaneously evaluate both of the axilla.
    [Abstract] [Full Text] [Related] [New Search]