These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Effects of radiolysis on yttrium-90-labeled Lym-1 antibody preparations.
    Author: Salako QA, O'Donnell RT, DeNardo SJ.
    Journal: J Nucl Med; 1998 Apr; 39(4):667-70. PubMed ID: 9544679.
    Abstract:
    UNLABELLED: The physical half-life of 2.6 days and 2.2 MeV beta emissions of 90Y provide excellent properties for radioimmunotherapy applications. However, the clinically useful beta particles may be a source of radiation-induced damage of 90Y-labeled immunoconjugate radiopharmaceuticals during preparation or short-term storage. The stability of 90Y-labeled Lym-1 antibody was studied in standard radiopharmacy conditions to establish a formulation at which radiolysis is not a problem. METHODS: Lym-1-21T-BAD immunoconjugate intermediate was prepared according to our standard procedure, then labeled with 90Y at 1, 2, 4 and 9.4 mCi/mg Lym-1 using 0.5 M tetramethylammonium acetate, pH 7, labeling buffer. Each mixture was challenged in diethylenetriaminepentaacetic acid to remove nonspecifically bound 90Y. The 90Y-21T-BAD-Lym-1 products were purified by centrifuged molecular sieving column chromatography. The radiochemical purity and immunoreactivity of each preparation was monitored daily by high-performance liquid chromatography (HPLC) and solid-phase radioimmunoassay, respectively, for 3 days. The preparation at 2 mCi/mg was also formulated in 4% (wt/vol) human serum albumin (HSA) overall and at 9.4 mCi/mg in five-fold water, 4 and 10% (wt/vol) HSA overall; all were monitored as above. RESULTS: The monomeric quality and purity profile of products at 1 and 2 mCi/mg were retained (> or = 80%) as was their immunoreactivity (> or = 75%) over 3 days. The radiochemical purity and immunoreactivity of the product at 4 mCi/mg declined to 65% and 28%, respectively, by 3 days after preparation and in just 48 hr, the product at 9.4 mCi/mg had degraded to 21% in radiochemical purity with only 3% immunoreactivity. The current HPLC data and earlier published chromatographic evidence did not support a compromised radiochemical integrity of 90Y-DOTA complexes by loss of 90Y from the DOTA chelate. CONCLUSION: Radiolysis of 90Y-labeled antibody preparations did not appear to be a problem at 90Y-21T-BAD-Lym-1 products < or = 2 mCi/mg. Human serum albumin proved to be an effective radioprotectant as the initial 100% immunoreactivity of the product at 2 mCi/mg was retained for 72 hr. The results underscore the need for appropriate formulations and dilutions of clinical doses of 90Y immunopharmaceuticals immediately after manufacture.
    [Abstract] [Full Text] [Related] [New Search]