  • Title: Acoustic mechanisms: canal wall-up versus canal wall-down mastoidectomy.
    Author: Whittemore KR, Merchant SN, Rosowski JJ.
    Journal: Otolaryngol Head Neck Surg; 1998 Jun; 118(6):751-61. PubMed ID: 9627232.
    Abstract:
    The contribution of the middle ear air spaces to sound transmission through the middle ear in canal wall-up and canal wall-down mastoidectomy was studied in human temporal bones by measurements of middle ear input impedance and sound pressure difference across the tympanic membrane for the frequency range 50 Hz to 5 kHz. These measurements indicate that, relative to canal wall-up procedures, canal wall-down mastoidectomy results in a 1 to 5 dB decrease in middle ear sound transmission below 1 kHz, a 0 to 10 dB increase between 1 and 3 kHz, and no change above 3 kHz. These results are consistent with those reported by Gyo et al. (Arch Otolaryngol Head Neck Surg 1986;112:1262-8), in which umbo displacement was used as a measure of sound transmission. A model analysis suggests that the reduction in sound transmission below 1 kHz can be explained by the smaller middle ear air space volume associated with the canal wall-down procedure. We conclude that as long as the middle ear air space is aerated and has a volume greater than 0.7 ml, canal wall-down mastoidectomy should generally cause less than 10 dB changes in middle ear sound transmission relative to the canal wall-up procedure.
    [Abstract] [Full Text] [Related] [New Search]