  • Title: Simultaneous determination of cyanide and thiocyanate in blood by ion chromatography with fluorescence and ultraviolet detection.
    Author: Chinaka S, Takayama N, Michigami Y, Ueda K.
    Journal: J Chromatogr B Biomed Sci Appl; 1998 Aug 25; 713(2):353-9. PubMed ID: 9746250.
    Abstract:
    An ion chromatographic method for the simultaneous determination of cyanide and thiocyanate in blood has been developed. After extraction by adding water and methanol to blood, cyanide was derivatized with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product of 1-cyanobenz[f]isoindole. This compound was detected with high sensitivity by fluorometry and the underivatized thiocyanate was detected by ultraviolet absorption. The detection limits were 3.8 pmol ml(-1) for cyanide and 86 pmol ml(-1) for thiocyanate, and the recoveries from blood were ca. 83% and ca. 100%, respectively. The proposed method was successfully applied to the analysis of both anions in blood from smokers, non-smokers and fire victims.