These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Simultaneous determination of cyanide and thiocyanate in blood by ion chromatography with fluorescence and ultraviolet detection. Author: Chinaka S, Takayama N, Michigami Y, Ueda K. Journal: J Chromatogr B Biomed Sci Appl; 1998 Aug 25; 713(2):353-9. PubMed ID: 9746250. Abstract: An ion chromatographic method for the simultaneous determination of cyanide and thiocyanate in blood has been developed. After extraction by adding water and methanol to blood, cyanide was derivatized with 2,3-naphthalenedialdehyde and taurine to give a fluorescent product of 1-cyanobenz[f]isoindole. This compound was detected with high sensitivity by fluorometry and the underivatized thiocyanate was detected by ultraviolet absorption. The detection limits were 3.8 pmol ml(-1) for cyanide and 86 pmol ml(-1) for thiocyanate, and the recoveries from blood were ca. 83% and ca. 100%, respectively. The proposed method was successfully applied to the analysis of both anions in blood from smokers, non-smokers and fire victims.[Abstract] [Full Text] [Related] [New Search]