  • Title: A randomized controlled trial of two methods for collection of sterile urine in neonates.
    Author: Tobiansky R, Evans N.
    Journal: J Paediatr Child Health; 1998 Oct; 34(5):460-2. PubMed ID: 9767511.
    Abstract:
    OBJECTIVE: To test whether urethral catheterization (UC) is better than suprapubic bladder aspiration (SPA) as a method for collection of sterile urine in neonates. METHODS: Thirty-three babies, requiring sterile collection of urine, were randomly assigned to either urethral catheterization (n=16), median gestation 28+/-3.9 weeks, median birth weight 968 g (range 650-4100) or SPA (n=17), median gestation 26+/-5.6 weeks, median birth weight 926 g (range 771-4070). The primary outcome was success in obtaining urine. Secondary outcomes were complications and urine culture results. RESULTS: Some urine was obtained in 11 (64.7%) babies in the SPA group and in 13 (81.2%) babies in the catheter group. Sufficient urine for analysis (>0.5 ml) was obtained in 10 (58.8%) in the SPA group versus 5 (31.2%) babies in the catheter group. There were more contaminated specimens in the catheter group but this was not significant in this small study. CONCLUSIONS: In this small randomized controlled trial urethral catheterization offered no significant advantage over SPA.
    [Abstract] [Full Text] [Related] [New Search]