These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Pitfalls in the sensitivity of HBsAg detection.
    Author: Babeş VT, Aderca I.
    Journal: Virologie; 1978; 29(2):87-91. PubMed ID: 97861.
    Abstract:
    A number of 1800 serum samples from apparently healthy subjects were tested by immunodiffusion (ID) and counterimmunoelectrophoresis (CIE) with a view to confirming the presence of HBsAg; results were uncertain in 21% of the cases. The enzyme immunoassay (ELISA kits) used to elucidate these uncertain reactions showed half of them to be negative. About 3% of the remaining sera, HBsAg-positive by ELISA, were positive by ID, but constantly negative by repeated CIE tests. Some possible explanations are suggested and the implications of such pitfalls in the interpretation of sero-epidemiological analyses are discussed.