These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Discrepancies in brain perfusion SPECT findings between Tc-99m HMPAO and Tc-99m ECD: evaluation using dynamic SPECT in patients with hyperemia.
    Author: Miyazawa N, Koizumi K, Mitsuka S, Nukui H.
    Journal: Clin Nucl Med; 1998 Oct; 23(10):686-90. PubMed ID: 9790044.
    Abstract:
    Discrepancies have been reported between the findings of Tc-99m HMPAO and Tc-99m ECD brain perfusion SPECT imaging. This study investigated the discrepancies in the accumulation of these tracers using dynamic SPECT to detect the super early phase of distribution. Thirteen patients with luxury perfusion or high flow states were studied with both dynamic and standard SPECT using Tc-99m HMPAO and Tc-99m ECD within 1-3 days. Standard SPECT showed discrepancies in 6 of 13 patients. Patients with meningioma and cerebral thrombosis had increased accumulation of Tc-99m HMPAO and decreased uptake of Tc-99m ECD. Patients with arteriovenous malformation, subarachnoid hemorrhage, and cavernous angioma had decreased accumulation of both tracers, but to different degrees. Dynamic SPECT showed increased or normal accumulation (i.e., essentially no discrepancy) in the first few minutes. However, Tc-99m HMPAO had a longer retention time than Tc-99m ECD in the ensuing 5-10 minutes. Dynamic SPECT revealed a similar accumulation pattern but different washout rates for the two tracers. Tc-99m HMPAO might be a more suitable tracer to detect high flow states or luxury perfusion because the findings on standard SPECT were more in agreement with those of dynamic SPECT using this tracer.
    [Abstract] [Full Text] [Related] [New Search]