These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Technetium-99m-labeled liposomes to image experimental colitis in rabbits: comparison with technetium-99m-HMPAO-granulocytes and technetium-99m-HYNIC-IgG.
    Author: Dams ET, Oyen WJ, Boerman OC, Storm G, Laverman P, Koenders EB, van der Meer JW, Corstens FH.
    Journal: J Nucl Med; 1998 Dec; 39(12):2172-8. PubMed ID: 9867164.
    Abstract:
    UNLABELLED: Scintigraphic techniques are routinely used for the evaluation of the extent and severity of inflammatory bowel disease. Currently, the radiopharmaceutical of choice is 99mTc-hexamethyl propyleneamine oxime (HMPAO)-leukocytes. We studied the imaging potential of two recently developed 99mTc-labeled agents, polyethylene glycol (PEG)-coated liposomes and hydrazinonicotinate (HYNIC) IgG, in a rabbit model of acute colitis, and compared them with that of 99mTc-labeled, granulocyte-enriched (>90%), white blood cells. METHODS: Acute colitis was induced in rabbits by retrograde instillation of trinitrobenzene sulfonic acid. After 48 hr, 37 MBq of each radiopharmaceutical was administered intravenously. Gamma camera images were taken at 0, 1, 2, 4, 10 and 24 hr. At 4 and 24 hr postinjection, groups of rabbits were killed, and the uptake of the radiolabel in the dissected tissues was determined. For each affected 5-cm segment, the colitis index (CI, affected-to-normal-colon-uptake ratio) was calculated and correlated to the macroscopically scored severity of inflammation. RESULTS: All three agents visualized the colitis lesions within 1 hr postinjection. The CI correlated with the severity of the abnormalities. With increasing severity, the CI at 4 hr postinjection for liposomes was 3.89+/-0.73, 4.41+/-0.47 and 5.76+/-0.65; for IgG 1.67+/-0.08, 3.92+/-0.44 and 6.14+/-0.65; and for granulocytes 2.90+/-0.09, 6.15+/-0.96 and 9.36+/-3.35. For liposomes, the CI further increased during 24-hr postinjection to 6.56+/-0.84, 8.50+/-0.53 and 10.61+/-1.34, respectively. The CI for the other two agents did not change significantly with time. CONCLUSION: In this rabbit model, 99mTc-labeled granulocytes, IgG and liposomes all rapidly visualized colonic inflammation. Granulocytes and liposomes showed the highest CI. Technetium-99m-labeled PEG-liposomes may be an attractive alternative for labeled leukocytes to image inflammatory bowel disease, because they can be prepared off the shelf and no handling of blood is required.
    [Abstract] [Full Text] [Related] [New Search]