These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Noninvasive cardiac output monitoring by aortic blood flow determination: evaluation of the Sometec Dynemo-3000 system. Author: Cariou A, Monchi M, Joly LM, Bellenfant F, Claessens YE, Thébert D, Brunet F, Dhainaut JF. Journal: Crit Care Med; 1998 Dec; 26(12):2066-72. PubMed ID: 9875922. Abstract: OBJECTIVE: The Sometec Dynemo-3000 system allows the permanent measurement of descending aorta diameter by an echographic (A-scan) device and the blood flow velocity by a pulse Doppler velocimeter. The Dynemo-3000 then furnishes a new hemodynamic parameter, i.e., descending aortic blood flow (ABF), which is a fraction of the cardiac output (CO). We evaluate the ability of this system to measure the aortic diameter and to accurately detect ABF changes. DESIGN: A case study prospective trial. SETTING: A 24-bed medical intensive care unit of a 1,100-bed university hospital. PATIENTS: Twenty critically ill patients fully sedated, mechanically ventilated, and monitored by a pulmonary artery catheter. INTERVENTIONS: CO values determined by conventional thermodilution method (TD-CO) and ABF were recorded during the study, which included two initial baseline periods, a dobutamine infusion (5 microg/kg/min) interval of 30 mins, and a third baseline period. To assess the accuracy of A-scan, aortic diameter was measured by transesophageal echocardiography. The difference between echocardiography and A-scan was used to determine bias and precision for aortic diameter measurements. TD-CO and ABF variations were analyzed using Kruskal-Wallis and Wilcoxon tests. Association between TD-CO and ABF values was determined by calculating the linear correlation coefficient. The ability of ABF to detect a TD-CO >6.0 L/min and its variations >13% was analyzed by determination of sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values. MEASUREMENTS AND MAIN RESULTS: Aortic diameter measurements by A-scan and bidimensional methods were 23.0+/-2.8 mm (SD) and 24.2+/-2.7 mm, respectively. Bias and precision were 1.1 mm and 1.4 mm (95% confidence interval: -1.9 to 3.7), respectively. During the course of dobutamine infusion, we observed a significant increase of TD-CO mean value from 6.65+/-1.53 L/min to 9.30+/-2.5 L/min (p=.0008), and a parallel and significant increase in ABF mean value from 4.34+/-1.18 L/min to 5.70+/-1.63 L/min (p= .0029). Absolute TD-CO and ABF values had a correlation coefficient of 0.80. For detection of an increased TD-CO, PPV and NPV were 87% and 86%, respectively. For detection of TD-CO changes >13%, PPV and NPV were 80% and 94%, respectively. CONCLUSIONS: The Dynemo-3000 system is able to display the real aortic diameter, which is one of the most important components of this noninvasive ultrasonic technique. When compared with TD-CO, the ABF determination provided by this ultrasonic device constitutes a reliable noninvasive tool for estimating CO and tracking its changes.[Abstract] [Full Text] [Related] [New Search]