These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Contraception with two levonorgestrel rod implants. A 5-year study in the United States and Dominican Republic. Author: Sivin I, Alvarez F, Mishell DR, Darney P, Wan L, Brache V, Lacarra M, Klaisle C, Stern J. Journal: Contraception; 1998 Nov; 58(5):275-82. PubMed ID: 9883382. Abstract: A 5-year trial of a two-rod contraceptive implant, which releases the progestin levonorgestrel (LNG rod), was conducted at four clinics with 594 women. Mean age and weight at admission were 25.5 years and 62.4 kg, respectively. Consent to continue through 5 years was sought and obtained when the 3-year cumulative pregnancy rate proved to be 0.8 per 100. No pregnancies occurred in the fourth or fifth years. The 5-year cumulative pregnancy rate was, therefore, 0.8 per 100 with an annual average pregnancy rate below 2 per 1000 women. Prolonged bleeding/spotting (8.2% of subjects) and irregular bleeding (5.6%) were the most frequently cited medical reasons for removal. Removals for headache (4.7%) and weight change (4.0%) were the next most frequent medical reasons. Between 1% and 2% of subjects during the 5-year trial sought removals for each of the following conditions: mood changes, lower abdominal pain, depression, or pain at the implant site. The mean annual continuation rate during the study was 77 per 100. Use per woman averaged 2.96 years. Mean removal time was 5.9 +/- 0.6 min. These data indicate that, for a 5-year period, the two LNG rod implants are equivalent to the six Norplant capsule implants with respect to safety and efficacy parameters, but permit easier and more rapid implant removal. The newly developed 2-rod levonorgestrel (LNG) implant system has a surface area only 44% that of Norplant yet provides LNG release rates and blood levels similar to the 6-capsule Norplant system. Clinical trials of the 2-rod implant system initiated in 1990 demonstrated an exceptionally low cumulative pregnancy rate (0.8/100) in the first 3 years of use. This paper reports on an extension of the original study for an additional 2 years. 594 women at 4 study sites in the US and the Dominican Republic completed 5 years of method use. No pregnancies occurred in the fourth and fifth years of use. Thus, the 5-year cumulative pregnancy rate was 0.8/100, with an average annual pregnancy rate below 2/1000 women. The mean annual continuation rate during the 5-year study period was 77/100 women, with an average duration of use of 2.96 years. The most frequent reasons for medical removal were prolonged bleeding/spotting (8.2% of women), irregular bleeding (5.6%), headache (4.7%), and weight gain (4.0%). Mean removal time was 5.9 minutes and complications occurred in only 2.3% of removals. Overall, these findings confirm that the 2-rod LNG implant contraceptive has an effectiveness equivalent to the 6-capsule implant for a 5-year period, with good acceptability and a substantially improved ease of removal.[Abstract] [Full Text] [Related] [New Search]