These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Determination of submicromolar concentrations of neurotransmitter amino acids by fluorescence detection using a modification of the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate method for amino acid analysis.
    Author: Liu H, Sañuda-Peña MC, Harvey-White JD, Kalra S, Cohen SA.
    Journal: J Chromatogr A; 1998 Dec 18; 828(1-2):383-95. PubMed ID: 9916319.
    Abstract:
    A sensitive method for quantitatively determining submicromolar levels of neurotransmitter amino acids (e.g. Asp, Glu and gamma-aminobutyric acid) in microdialysates from brain and cerebrospinal fluids is reported. 6-Aminoquinolyl-N-hydroxy-succinimidyl carbamate (AQC) was employed as the derivatization reagent, followed by HPLC separation and fluorescence detection of the derivatives. The derivatization was conducted simply by mixing the AQC directly with the microdialysis samples. The reaction was complete within seconds after mixing at room temperature. Separation development optimizing the gradient profile, eluent pH and column temperature resulted in an excellent separation of the required amino acids in less than 30 min. Other resolved amino acids in the same profile include Gly, taurine, and Pro. Recoveries for the amino acids of interest spiked into high salt containing perfusion buffers were greater than 97%. The sensitivity of the method was increased by employing a 16-microliter flow cell in the detector and analyzing 20-microliter aliquots of the derivatization mixtures. With the optimized conditions, the detection limits were 3-7 nM (fmol/microliter). Typical reproducibility (%R.S.D.) for quantitation of these amino acids at submicromolar levels was approximately 2%. Excellent linearity (r2 > 0.999) was achieved over the range 0.2-20 microM. The low detection limits permitted the analysis of a number of different microdialysate samples including those from cerebrospinal fluid, as well as substantia nigra and hypothalamus from brain samples, even at basal levels where gamma-aminobutyric acid concentration may be < 50 nM. The excellent sensitivity made it easy to distinguish basal from stimulated levels of neurotransmitter amino acids, even from sample sizes as small as 10 microliters.
    [Abstract] [Full Text] [Related] [New Search]