These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Quantitative determination of endogenous retinoids in mouse embryos by high-performance liquid chromatography with on-line solid-phase extraction, column switching and electrochemical detection. Author: Sakhi AK, Gundersen TE, Ulven SM, Blomhoff R, Lundanes E. Journal: J Chromatogr A; 1998 Dec 18; 828(1-2):451-60. PubMed ID: 9916324. Abstract: An isocratic high-performance liquid chromatographic method for the determination of 9-cis-retinoic acid, 13-cis-retinoic acid, all-trans-retinoic acid and all-trans-retinol in mouse embryos using on-line solid-phase extraction and column switching in combination with electrochemical detection has been developed. The method was validated using retinoids in albumin solutions and 13-cis-acitretin was used as internal standard. About 370 microliters of albumin solution was injected on a 10 x 2.1-mm I.D. pre-column packed with Bondapak C18, 37-53-micron particles. The proteins were washed to waste within 5 min using as mobile phase, a 1:3 dilution of mobile phase 2, which consisted of acetonitrile-methanol-2% ammonium acetate-glacial acetic acid (79:2:16:3, v/v). Components retained on the pre-column were back-flushed to and separated on the 250 x 4.6-mm I.D. Suplex pKb-100 analytical column using mobile phase 2. The retinoids were detected electrochemically at +750 mV using a coulometric electrochemical detector. The total analysis time was about 20 min. Recoveries were in the range of 86-103%. The mass limits of detection were about 10 pg and 25 pg for the retinoic acids and all-trans-retinol, respectively. The intra-assay precision, reported as relative standard deviation, was in general better than 4% (n = 6) for the four retinoids. Inter-assay precision was in the range 3-4% (n = 10). The method was applied for determination of endogenous retinoids in 9.5 day-old mouse embryos. A 340-microliter solution containing 100 microliters of embryo homogenate (1.64 embryos) was analyzed. The concentrations of all-trans-retinol and all-trans-retinoic acid were found to be 279 pg per embryo and 75.8 pg per embryo, respectively. The amount of 13-cis-retinoic acid and 9-cis-retinoic acid was below the detection limit.[Abstract] [Full Text] [Related] [New Search]